Login
Trafo Engineering
⚡ Turnaround: Same-Day On-Site 🛡️ BDV > 65 kV Guarantee

Oil Centrifuging

High-Vacuum 2-Stage Transformer Oil Dehydration, Degassing & BDV Restoration

Mobile high-vacuum transformer oil purification, dehydration, degassing, and sub-micron particle filtration. Restores dielectric breakdown voltage (BDV) above 65kV on-site without plant shutdown.

Oil Centrifuging
Trafo Heavy Engineering Workshop ISO 9001:2015 & IEC Certified Testing Facilities

Key Deliverables & Specifications

6,000 LPH High-Vacuum Capacity

Double-stage rotary vane vacuum system delivering deep negative pressure.

Guaranteed Dielectric BDV > 65 kV

Rigorous before & after testing with on-site printed dielectric breakdown certificates.

Sub-Micron Multi-Stage Filtration

1-micron depth filtration cartridges capturing microscopic sludge.

Live On-Line Circulation Capability

Equipped with Buchholz relay trip-bypass and auto de-aeration for live filtration.

Engineering Scope & Capabilities

Mobile High-Vacuum Transformer Oil Centrifuging & Filtration

Transformer dielectric oil degrades over time due to moisture absorption from the atmosphere, paper aging, and oxidation sludge. Trafo Engineering operates a fleet of mobile high-vacuum oil centrifuging and purification units equipped to service transformers on-site anywhere in Bangladesh.

Key Benefits of High-Vacuum Oil Filtration

  • Dielectric Strength Restoration: Elevates BDV from degraded levels (<25kV) to fresh laboratory standards (>65kV–80kV).
  • Moisture Extraction: Removes dissolved and emulsified water down to < 10 ppm via vacuum flash evaporation at 60°C.
  • Combustible Gas Removal: Extracts hydrogen, acetylene, and methane gases to mitigate internal arc explosion risks.
  • Sub-Micron Particulate Removal: 1-micron filter cartridges remove suspended carbon and fiber debris.

Step-by-Step Engineering Methodology

1

Initial Oil Sampling & BDV Test

Sampling bottom and top oil to benchmark breakdown voltage, moisture, and color index.

2

Closed-Loop Heated Vacuum Circulation

Heating oil to 60°C and circulating through double-stage vacuum degassing chambers.

3

Fine Cartridge De-Sludging

Passing heated oil through 1-micron microfiber filter arrays under vacuum.

4

Post-Treatment BDV Validation & Certification

Multi-shot automated BDV testing to certify compliance with IEC 60296 standards.

Diagnostic & Calibration Instruments

Testing Instrument / Apparatus Capability & Standard Compliance
Mobile Oil Purification Plant Trafo Tech 6000 LPH High-Vacuum 2-Stage Unit
Automated Oil BDV Tester Foster / Trafo-Tech 80kV Automated Breakdown Tester
Karl Fischer Moisture Titrator PPM Water Content Precision Analyzer (IEC 60814)
Vacuum Pump System Edwards 2-Stage Mechanical Booster Vacuum System

Frequently Asked Technical Questions

As per IEC guidelines, distribution transformers should have their oil tested annually and filtered every 2 to 3 years, or immediately if BDV drops below 30 kV.
Yes, our advanced filtration plants feature electronic air trap interlocks and surge protection allowing safe on-line filtration without interrupting factory production.
⚡ Fast Response Guarantee

Book Oil Centrifuging

Get an on-site engineer dispatched or receive a formal branded quotation.

Direct Engineer Line +880 1700-000000

Available 24 hours a day for factory power outages and emergency substation repairs.

HOME PRODUCTS
QUOTE
CART